130-K
Tab connector

GENERAL INFORMATION
TECHNICAL DATA
Over Voltage Category
III
III
II
Pollution Severity Level
3
2
2
Rated Voltage
250 V
320 V
400 V
Rated Impulse Voltage
4 kV
4 kV
4 kV
Rated current: 12 A
Rated insulation voltage: 250 V acc. to EN 60998-1
Hole in PCB: ø 1.4 mm
RATINGS
Current [A] |
Voltage [V] |
Group |
AWG |
Torque [Nm] |
|
---|---|---|---|---|---|
![]() |
22 | 300 | B | ||
10 | 300 | D | |||
![]() |
22 | 300 | B | ||
10 | 300 | D, E |
Download PDF
TECHNICAL DRAWINGS
MATERIALS
Moulding: PBT, natural, V-0
Comparative tracking index: CTI ≥ 275
Insulating group: IIIa
Temperature range: -40°C up to 130°C
Solder pin: 0,8 x 0,8 mm, Tin plated brass
Tab: 6,3 x 0,8 mm, Tin plated brass
OPTIONS / ACCESSORIES
- Consecutive numbering
- Special marking according to drawing
- Self-adhesive marking strip
- Pitch of 10 mm for larger clearance and creepage distances
- Tab for solder brige